0000418: in DPsFnshr.ini CPU KTD path is incorrect
Setting DP BASE stable (as well as DPs_BASE_801RC2) to KTD CPU driver in a Windows 2003 environment
in DPsFnshr.ini the CPU KTD path is incorrect, missing the letter U
> KTD = "paths:D\C;D\CP;D\L;D\M;D\W"
This results in an error prompt during setup and an error log in the finisher log file: "because the directory "C:\D\CP" did not exist."

No tags attached.
Issue History
2008-03-05 03:32uers1New Issue
2008-03-05 03:32uers1Statusnew => assigned
2008-03-05 03:32uers1Assigned To => BashratTheSneaky
2008-03-05 03:32uers1Destination OS Platform => wnt5_x86-32 (Windows Server 2003)
2008-03-05 03:32uers1Installation Platform => disc (CD/DVD)
2008-03-05 03:32uers1DriverPacks => CPU
2008-03-05 03:32uers1DriverPacks Method => 2
2008-03-05 03:32uers1DriverPacks Finisher Method => GUIRunOnce
2008-03-05 03:33uers1Note Added: 0000724
2008-05-04 18:59OverFlowAssigned ToBashratTheSneaky => OverFlow
2008-05-04 18:59OverFlowStatusassigned => resolved
2008-05-04 18:59OverFlowResolutionopen => fixed
2008-09-10 07:43OverFlowStatusresolved => closed

Notes
(0000724)
uers1   
2008-03-05 03:33   
of course this results also in no CPU driver kept on disk.